1001 NW Technology Drive, Lee's Summit, MO 64086 // (800) 305-5198 // (816) 347-0143 Fax // info@viracor-eurofins.com
3900 - Hepatitis D Virus (HDV) Qualitative Real-time RT-PCR - 3/29/2024 2:01:00 PM
Page of
Hepatitis D Virus (HDV) Qualitative Real-time RT-PCR
Test Code: 3900
Clinical and Procedure
Clinical Utility
Hepatitis D virus (HDV) is an incomplete RNA virus that requires the helper function of Hepatitis B virus (HBV) envelope proteins (HBSAg) to replicate. The HDV Real-time RT-PCR assay detects HDV RNA in serum or plasma.
Procedure
Extraction of nucleic acid from specimen, followed by reverse transcription of viral RNA, then amplification and detection of cDNA using real-time, quantitative PCR. An internal control is added to ensure the extraction was performed correctly and the PCR reaction was not inhibited. This test has not been cleared or approved for diagnostic use by the U.S. Food and Drug Administration.
Specificity
The assay is specific for Hepatitis D.
Turnaround Time
7 business days from receipt of specimen.
Specimen Information
Specimen TypeOrder CodeCPT CodeNY ApprovedVolumeAssay RangePlasma (1)390187798Yes
2 mL (min. 0.5 mL)
Detected/Not Detected
Special Instructions
-
Collect 4-5 mL whole blood in EDTA or ACD tube.
-
Avoid using gel separator tubes; samples collected in gel separator tubes have increased rate of PCR inhibition.
-
Centrifuge (optional) and transfer 2 mL plasma to sterile, screw top tube.
-
Alternatively plasma can be shipped in the original collection tube without centrifugation.
-
Can be shipped at ambient or refrigerated temperature Monday through Friday.
-
Specimens shipped at ambient temperature must be received within 7 days of collection.
Serum (1)391087798Yes
2 mL (min. 0.5 mL)
Detected/Not Detected
Special Instructions
-
Collect 4-5 mL whole blood in red top tube.
-
Avoid using gel separator tubes; samples collected in gel separator tubes have increased rate of PCR inhibition.
-
Centrifuge and transfer 2 mL serum to sterile, screw top tube.
-
Can be shipped at ambient or frozen temperature Monday through Friday.
-
Specimens shipped at ambient temperature must be received within 7 days of collection.
Shipping
Ship Monday through Friday. Friday shipments must be labeled for Saturday delivery. All specimens must be labeled with patient's name and collection date. A Eurofins Viracor test requisition form must accompany each specimen. Multiple tests can be run on one specimen. Ship specimens FedEx Priority Overnight® to: Eurofins Viracor, 18000 W 99th St. Ste, #10, Lenexa, KS 66219.
Causes for Rejection
Grossly hemolyzed plasma/serum specimens, specimens beyond their acceptable length of time from collection as listed in the specimen handling, or specimen types other than those listed.
Disclaimer
Specimens are approved for testing in New York only when indicated in the Specimen Information field above. The CPT codes provided are based on Eurofins Viracor 'sinterpretation of the American Medical Association's Current Procedural Terminology (CPT) codes and are provided for informational purposes only. CPT coding is the sole responsibility of the billing party. Questions regarding coding should be addressed to your local Medicare carrier. Eurofins Viracor assumes no responsibility for billing errors due to reliance on the CPT codes illustrated in this material.
References
Price, J. An update on Hepatitis B, D and E Viruses. (2014)
Topics in Antiviral Medicine
21(5):157-163.